Emerson I2p-100 Electrical Converter New Original Genuine Controller

Product Details
Customization: Available
Valve Type: Diaphragm Valve
Brand Name: Emerson
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • Emerson I2p-100 Electrical Converter New Original Genuine Controller
  • Emerson I2p-100 Electrical Converter New Original Genuine Controller
  • Emerson I2p-100 Electrical Converter New Original Genuine Controller
  • Emerson I2p-100 Electrical Converter New Original Genuine Controller
  • Emerson I2p-100 Electrical Converter New Original Genuine Controller
  • Emerson I2p-100 Electrical Converter New Original Genuine Controller
Find Similar Products

Basic Info.

Model NO.
I2P-100
Warranty
1year
Place of Origin
Guangdong, China
Customized Support
Oemodmobm
Model Number
I2p-100
Transport Package
Carton Box
Specification
0.5kg
Production Capacity
100

Product Description

Product Details

 
Input Signal Available as standard with 4‐20 mA. User configurable by dip switch for split ranging, see table below. Output
Signal(1) Available as standard 0.2 to 1.0 bar (3 to 15 psig), 0.4 to 2.0 bar (6 to 30 psig), or 0.14 to 2.3 bar (2 to 33 psig).
User configurable by dip switch selection and zero and span potentiometer adjustment, see table below. Input Signal Output
Pressure Bar psig 4‐20 mA DC 0.2 to 1.0 3 to 15 0.4 to 2.0 6 to 30 0.14 to 2.3 2 to 33 4‐12 mA DC 0.2 to 1.0 3 to 15 12‐20 mA DC
0.2 to 1.0 3 to 15 Equivalent Circuit The i2P‐100 equivalent circuit is a series circuit consisting of a constant voltage drop
(battery) of approximately 4 VDC and a total resistance of 40 ohms. Input is shunted by two 6.8 V zener diodes (see figure 9).
Supply Pressure(2) Recommended: 0.3 bar (5 psi) higher than upper range limit of output signal Maximum: 3.4 bar (50 psig) Medium:
Air or Non-Corrosive Natural Gas Per ISA Standard 7.0.01 A maximum 40 micrometer particle size in the air system is acceptable.
Further filtration down to 5 micrometer particle size is recommended. Lubricant content is not to exceed 1 ppm weight (w/w) or
volume (v/v) basis. Condensation in the air supply should be minimized. Pressure Dew Point: At least 10C less than the lowest
ambient temperature expected Per ISO 8573-1 Maximum particle density size: Class 7 Oil content: Class 3 Pressure Dew Point: Class
3 Maximum Steady-State Flow Rate Refer to tables 3 and 4 Maximum Output Air Capacity(3) 8.0 m3/hr (300 scfh) at 1.4 bar (20 psig)
supply pressure Performance(4) Reference Accuracy: 1.0% of full scale output span; includes combined effects of hysteresis,
linearity, and deadband Independent Linearity: 0.5% of full scale output span Hysteresis: 0.4% of full scale output span
Frequency Response: Gain is attenuated 3 dB at 3 Hz with transducer output signal piped to a typical instrument input Temperature
Effect: 0.14% per degrees Celsius (0.075% per degrees Fahrenheit) of span Supply Pressure Effect: 0.2% of full scale output span
per psi supply pressure change Vibration Effect: Less than 1% of full scale output span when tested to ISA S75.13 Electromagnetic
Compatibility Meets EN 61326‐1:2013 Immunity-Industrial locations per Table 2 of EN 61326‐1 Standard. Performance is shown in
table 2 below. Emissions-Class A ISM equipment rating: Group 1, Class A Operating Ambient Temperature Limits(2) -40 to 85C (-40 to
185F) Electrical Seal Single sealed device per ANSI/ISA 12.27.01 Hazardous Area Approvals CSA-Intrinsically Safe, Explosion-proof,
Type n, Dust‐Ignition proof (Canada) FM-Intrinsically Safe, Explosion-proof, Type n, Non‐incendive, Dust‐Ignition proof (United
States) ATEX-Intrinsically Safe, Flameproof, Type n IECEx-Intrinsically Safe, Flameproof, Type n Continued on next page
(continued) Instruction Manual D103198X012 i2P-100 Transducer November 2023 4 Table 1. Specifications (continued) Hazardous Area
Approvals (continued) CUTR- Customs Union Technical Regulations INMETRO- National Institute of Metrology, Quality, and Technology
(Brazil) KTL-Korea Testing Laboratory (South Korea) NEPSI- National Supervision and Inspection Centre for Explosion Protection and
Safety of Instrumentation (China) UKEx-Intrinsically Safe, Flameproof, & Dust Type n & Dust (United Kingdom) Contact your Emerson
sales office or refer to the i2P-100 product page at for approval specific information Electrical Housing When Remotely
Vented No Remote Venting CSA-Type 4X Encl. FM-NEMA 4X ATEX-IP66 IECEx-IP66 CSA-Type 3 Encl. FM-NEMA 3 ATEX-IP64 IECEx-IP64
Connections Supply and Output Pressure: 1/4 NPT internal connection Vent: 1/4 NPT internal Electrical: Standard 1/2 NPT Wire Size:
18 to 22 AWG Adjustments(1) Zero and Span: Trim potentiometers (20 turn) for zero and span adjustments are located under the
housing cap (see figure 10). Switch: Allows input signal split range and user‐configurable 0.14 to 2.3 bar (2 to 33 psig) output.
Mounting Position Actuator pipestand or surface Approximate Weight (Transducer Only) 2.5 kg (5.5 lbs) Actuator Stroking Time See
figure 2 Declaration of SEP Fisher Controls International LLC declares this product to be in compliance with Article 4 paragraph 3
of the PED Directive 2014/68/EU and Part 1, Requirement 8 of the PESR Regulation. It was designed and manufactured in accordance
with Sound Engineering Practice (SEP) and cannot bear the CE marking related to PED compliance or the UKCA mark related to the
PESR Regulation. However, the product may bear the CE or UKCA marking to indicate compliance with other applicable European
Community Directives or UK Regulations (Statutory Instruments).
 
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Nice to meet you and thank you for the information. We have a wide range of stock products including valve instruments, fittings,
and spare parts from brands such as Rotork, Samson, ASCO, TOPWORX, GO SWITCH, YTC, Masoneilan, and more. With years of
specialization in valves and valve fittings, we have established a stable and robust supply chain and maintain a large inventory
at competitive prices. I am committed to offering you the best prices to demonstrate our sincerity. We provide comprehensive
services for equipment, installation, commissioning, maintenance, and technical modification. Many European and American brands
are available in stock at competitive prices.Thank you and best wishes. If you have any related product needs, please feel free to contact us. Feel free to let me know if you need any further adjustments!
 
 
 
 
 
Recommended Products
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
Emerson I2p-100 Electrical Converter New Original Genuine Controller
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier